MudAndTapeSheets, mud, tape and screws for a room, with the waste counted.

Drywall for a 15 × 15 ft ceiling: ½″ 4 × 8 on 16″ joists

Ceiling boards
8× ½″ 4 × 8 ft
225 ft² ceiling plus 12% — framing at 16″ o.c.
Ceiling planboards run across the joists · joists at 16″ o.c.8× ½″ 4 × 8 ft315 screws at 12″51 lb per boardSag: OK
Boards12% waste — ceilings cut around fixtures8½″ 4 × 8 ft
Ceiling area15 × 15 ft225ft²
Sag check½″ 4 × 8 ft is rated for framing at 16″ o.c.OK
Screws12″ spacing on ceilings, not 16″ — about 1 lb box315screws
Joint compound0.54.5 gal buckets
Paper tape102linear ft
Weight per boardoverhead — a panel lift is worth the hire, and it is not optional on ⅝″ 12 ft boards51lb
Fixture cut-outscut after the board is up, from the joist positions marked on the floor6holes
Length
15 ft
Width
15 ft
Board
½″ 4 × 8
Joist spacing
16 in o.c.
Light fittings
6

A ceiling is not a wall lying down

Three things change, and all three are in the standards rather than in preference.

Thickness depends on framing spacing. ½″ standard board sags between joists at 24″ on center — it looks fine for a season and then develops a slow wave that no skim coat corrects. At 24″ you want ⅝″, or ½″ sag-resistant board rated for it.

Sag check for this ceiling: OK.

Screws every 12 inches, not 16. A ceiling board fights gravity for its whole life; a wall board rests on the plate. That is 315 screws here.

Boards run perpendicular to the joists. A board bridging several joists is far stiffer than one running along a single bay, and it spreads load across the joints instead of concentrating it.

What to buy

8 boards of ½″ 4 × 8, 0.5 buckets of compound, 102 linear ft of tape.

Waste is 12% rather than the 10% used on walls, because a ceiling gets cut around 6 light fitting6 plus vents and the perimeter.

Each board weighs 51 lb, overhead

A panel lift is worth the hire. On the heavier boards it is not a convenience — it is the difference between doing the job and dropping a board on somebody.

Mark the joists on the floor first

Once a board is up you cannot see the framing, and hunting for it with a screw gun leaves a ceiling full of holes that all have to be filled.

Notes

  • ½″ 4 × 8 ft is rated for 16″ framing. Note it is the **board** that carries the rating, not the paint or the texture over it.
  • **Screws every 12 inches on a ceiling**, not 16. A ceiling board fights gravity for its whole life; a wall board rests on the plate. That difference is why ceiling screw patterns are tighter, and why a ceiling that was screwed to wall spacing shows fastener pops first.
  • Run the boards **perpendicular to the joists**. A board bridging several joists is far stiffer than one running along a single bay, and it spreads the load across the joints instead of concentrating it.
  • Each board weighs 51 lb overhead. Two people can manage it, but a panel lift makes the joints tighter because nobody is fighting the weight while positioning.
  • Mark the joist positions on the floor before you lift a board. Once it is up you cannot see them, and hunting for framing with a screw gun leaves a ceiling full of holes.
  • 12% waste rather than the 10% used on walls — ceilings are cut around 6 lights, plus any fan boxes, vents and the perimeter.

Nearby sizes

Read more